Product Introduction1. The product consists of a working part and a rod or handle, where the working part is made of SE-Wire nickel-titanium alloy.2. The material is heat-treated. It is more flexible than traditional nickel-titanium alloy and has stronger resistance to bending fatigue. RECIPROC blue uses a predetermined motor reciprocating motion mode, which uses VDW.SILVERRRECIPROC R, VDW.GOLDRRECIPROCR settings.3. The instrument adopts a unique reciprocating motion design.4. RECIPROCR blue is packaged in aluminum foil and is sterilized.Product ApplicationThis product is a tool for preparing root canals.Product Use1. Form a straight path2. Select the RECIPROCRblue instrument to be used:The primary apex file clears the root canal and can reach the estimated working length with a clamping feeling.For 10# primary apex file, choose R25;For 20# primary apex file, choose R40;For 30# primary apex file, choose R503. The first step of using RECIPROCRblue:Before selecting the corresponding RECIPROCRblue instrument, use C-PILOTR or K file to estimate the root canal length. Use the start and stop plate on the instrument to set 2/3 of the estimated length.Next Steps1. Fill the pulp cavity with irrigating solution.2. Insert the instrument into the root canal. (Press the motor foot switch when the instrument reaches the root canal opening).3. Push the instrument up and down with minimal pressure in the apical direction. Each up and down pull should not exceed 1 mm, and three pulls should not exceed 3 mm. One up and down pull = one back and forth, and the instrument should be removed from the root canal after completing 3 back and forth.4. Clean the debris on the surface of the file body with a cleaning table and check the instrument for wear.5. Irrigate the root canal generously with irrigating solution.6. Check the patentness of the root canal with C-PILOTR Pioneer File ISO Size 10.7. Repeat steps 3-6 to 2/3 of the estimated working length (by the position marks of the start and stop pieces).8. After preparing 2/3 of the working length, use a root gauge to measure the exact working length.9. Then repeat steps 3-6 until the full working length is reached.Precautions1. The instrument may only be used by qualified personnel in a dental office or hospital.2. RECIPRO-CRblue instruments are sterile disposable instruments and may not be reused. Instruments cannot be sterilized.3. Check the instruments for signs of wear during each work step.4. Clean the instrument grooves in the cleaning station after three pulls and flush the root canal according to the corresponding flushing regulations.5. Only very light pressure may be used with RECIPRO-CRblue instruments. If resistance can be felt in the root canal, the instrument cannot be advanced further, clean the RECIPRO-CRblue instrument, flush the root canal according to the corresponding flushing regulations, and check the root canal for patency with a #10C pioneer file. Then continue with preparation.6. Rubber dam must be used.